Eaton(Model-9145) 3KVA Online UPS with Long Backup
Type: Online/double-conversion
- Output Power Wattage: 2400 W
- Input Voltage: 200 V|Output Voltage: 220 V
- Input Frequency: 50|Output Frequency: 50
- W x H x D: 19.2 cm x 34.7 cm x 46 cm
- Communications Card Slots: Intelligent Slot for optional SNMP Card / AS 400/ Modbus Card. Power Management Software: WINPOWER power management software, included on CD
- Audible Noise: <50dB. Operating Temperature: 0-45°C. Standards and Compliance: RoHS. Safety markings: IEC 62040-1. Relative Humidity: 0-90% Non Condensing
- Reviews (0)
- Product Specifications
- Technical Specifications
Be the first to review “Eaton(Model-9145) 3KVA Online UPS with Long Backup”
- Topology: Online double-conversion. Configuration: Tower. Color: Black. Warranty: 12 Months. Rating (VA/Watts): 3000VA/2400W. Dimensions (H x W x D, mm): 347 x 192 x 460. Weight (kg): 31.
- Connection: Hardwired – see manual for terminal block layout. Input Voltage Range: 110~300VAC. Nominal Voltage: 208/220/230/240VAC. Frequency: 50/60Hz, auto-sensing. Frequency Range: 45-55Hz or 54-66Hz. Input Power Factor: 0.99. THDI < 5% with full load.
- Voltages: 220/230/240VAC. Output voltage regulation <2 %. Voltage THD<3% THD (Linear Load); <5% THD (Non-Linear Load). Output Receptacles (4) IEC-320-C13 C13 Overload Capacity 1min @ 105%~110% load; 30s @ 110%~125% load Power Factor 0.99 Output Frequency 45-55Hz/54-66Hz Load Crest Factor 3:1.
- Battery Type: 8 x 12V (7Ah). Recharge Time: 5 hours to recover 90% capacity. User Interface: Four buttons (on/off, select, enter, mute). LEDs: LCD Display with measurements (Input/Output/Bypass V & Hz, Battery Voltage & % capacity, remaining time and level indicator, Load % & level Indicator, Alarm codes).
Eaton 9145 3000VA Tower, w/o Battery
General | |
Topology | Online double-conversion |
Configuration | Tower |
Style Number | 9145 3000in XL |
Part Number | 9145 3000in XL |
Color | Black |
Rating (VA/Watts) | 3000VA/2400W |
Dimensions (H x W x D, mm) | 347 x 192 x 460 |
Weight (kg) | 13 |
Electrical Input | |
Connection |
(1) IEC-320-C20
|
Input Voltage Range | 110~300VAC |
Nominal Voltage | 208/220/230/240VAC |
Frequency | 50/60Hz, auto-sensing |
Frequency Range | 45-55Hz or 54-66Hz |
Input Power Factor | 0.99 |
THDI | < 5% with full load |
Electrical Output | |
Voltages | 220/230/240VAC |
Output voltage regulation | <2 % |
Voltage THD | <3% THD (Linear Load); <5% THD (Non-Linear Load) |
Output Receptacles |
(6) IEC-320-C13
|
Overload Capacity | 1min @ 105%~110% load; 30s @ 110%~125% load |
Power Factor | 0.99 |
Output Frequency | 45-55Hz/54-66Hz |
Load Crest Factor | 3:1 |
Battery | |
Battery Type | No internal batteries |
Communications | |
User Interface | Four buttons (on/off, select, enter, mute) |
LEDs | LCD Display with measurements (Input/Output/Bypass V & Hz, Battery Voltage & % capacity, remaining time and level indicator, Load % & level Indicator, Alarm codes) |
Communications Card Slots | Intelligent Slot for optional SNMP Card / AS 400/ Modbus Card |
Power Management Software | WINPOWER power management software, included on CD |
Environmental & Standards | |
Audible Noise | <50dB |
Operating Temperature | 0-45°C |
Standards and Compliance | RoHS |
Safety markings | IEC 62040-1 |
Relative Humidity | 20-90% Non Condensing |